DUCTIQ
Duct static pressure calculator. Round, rectangular and flat oval, full fittings and plant library, Darcy–Weisbach with Colebrook friction factors. Prints a design report with methodology.
COSTIQ
Hourly to annual running costs from kW, watts or amps with a guided duty cycle, plus a brand comparison table to sell the efficient option.
PUMPIQ
Pump sizing by total dynamic head: static lift, pipe friction, valves and equipment losses at your design flow. Gives the duty point to take to a pump curve, with a printable report.
HVACIQ
Air conditioning heat load calculator. Fabric, solar, glazing, occupancy and ventilation loads with real psychrometrics — sensible, latent and total kW, with a printable report.
FILTERIQ
Face velocity check, ISO 16890 grade recommendation by application, and filter bank layout with standard 610 modules. Printable A4 selection sheet.
CHILLIQ
Coolroom refrigeration load calculator. Panel transmission, infiltration, product pull-down and internal gains, sized over compressor run time. Printable report.
FREEZEIQ
Freezer room load calculator with three-stage product freezing: sensible, latent heat of fusion and sub-freezing loads. Printable report.
CHILLERIQ
Chiller sizing calculator. Duty in kW at leaving water temperature, flow at delta-T, glycol corrections and freeze protection check. Prints a duty specification ready to send to a supplier.
GAUGEIQ
Refrigerant PT, superheat and subcooling. Eight refrigerants, gauge or absolute, glide handled properly. Prints a commissioning record.
ROCKETIQ
Real Tsiolkovsky delta-v, TWR, computed gravity losses and a payload-to-orbit solver — validated against Falcon 9. Prints a Flight Feasibility Report.
SLABIQ
Concrete calculator: slabs, footings and columns to total m³ with waste, ready-mix order size and bag count. Printable order summary.
CRANEIQ
Indicative crane match from load weight, radius and lift height across pick & carry, city, all-terrain, crawler and tower classes. Printable lift enquiry sheet for crane company confirmation.
PACCOMMIQ
Package unit commissioning: live superheat and subcooling with pass ranges, amps vs nameplate with imbalance flags, supply/return ΔT, mechanical checks and optional air balance. One signable record.
CASCOMMIQ
Cassette commissioning: register, live SH/SC with pass ranges, amps vs nameplate with imbalance flags, mechanical checks and optional per-outlet air balance. Signable record from your phone.
DUCTCOMMIQ
Ducted split commissioning: live SH/SC with pass ranges, amps vs nameplate, supply/return ΔT both modes, mechanical checks and optional air balance across the outlets. Signable record.
HIWALLCOMMIQ
Hiwall split commissioning: register, live SH/SC with pass ranges, amps vs nameplate with imbalance flags and mechanical checks. The quick signable record for the everyday split.
FLOORCOMMIQ
Floor console commissioning: register, live SH/SC with pass ranges, amps vs nameplate with imbalance flags, mechanical checks and optional air balance. Signable record from your phone.
TBARCOMMIQ
T-bar cassette commissioning: register, live SH/SC with pass ranges, amps vs nameplate with imbalance flags, mechanical checks and optional air balance. Signable record from your phone.
AHUCOMMIQ
Air handling unit commissioning: live SH/SC, amps vs nameplate with imbalance flags, supply and return static pressure, airflow, mechanical checks and optional air balance. Signable record.
MULTICOMMIQ
Multi-split commissioning: repeatable indoor-unit register against one outdoor, live SH/SC with pass ranges, amps vs nameplate with imbalance flags and mechanical checks. Signable record.
VRFCOMMIQ
VRF commissioning: indoor-unit register against one condensing unit, live SH/SC with pass ranges, amps vs nameplate with imbalance flags and mechanical checks. Signable record from your phone.
FANCOMMIQ
Fan commissioning for inline, curb-mounted, roof exhaust, axial and centrifugal fans: nameplate vs actual, per-phase amps with imbalance flags, mechanical checks and optional air balance.
QUENCHIQ
Size an MRI helium quench pipe. Estimates helium release, peak quench flow and indicative pressure drop against the magnet's back-pressure limit.
VERIFYIQ
Certificate of test to AS/NZS 3000 Section 8. Visual inspection, per-circuit mandatory tests and sign-off. AU and NZ. Prints to A4.
FIREIQ
Baseline data sheet for detection, sprinkler, hydrant, EWIS and smoke control. AU (AS 1670 / AS 1851) and NZ (NZS). Prints to A4.
PRESSIQ
Hydrostatic and pneumatic pressure test record to AS/NZS 3500, with backflow, TMV and disinfection sections. AU and NZ. Prints to A4.
GASIQ
Gas soundness (leakage) test and appliance commissioning. AU (AS/NZS 5601.1) and NZ (NZS 5261). Let-by, purge and appliance data. Prints to A4.